Tags: Fin Cooler

Cross flow induced draft

About Cross flow induced draft: The counter-flow and cross flows are two basic designs of cooling towers based on the fundamentals of heat exchange. It is well known that counter flow heat exchange is more effective as compared to cross flow or parallel flow heat exchange. Cross-flow cooling towers are provided with splash fill of […]

Counter flow forced draft

About  Counter flow forced draft: In the counter flow induced draft design, hot water enters at the top, while the air is introduced at the bottom and exits at the top. Both forced and induced draft fans are used. In cross flow induced draft towers, the water enters at the top and passes over the […]

Evaporative Condensers

Evaporative Condensers Evaporative condensers improve the heat rejection process by using the cooling effect of evaporation. Water is sprayed over the condensing coil from above while air is simultaneously blown up through the coil from below to naturally lower the condensing temperature. Evaporative condensers provide heat rejection for many types...

Plume Abated Cooling Towers

About Plume Abated Cooling Towers: The cooling tower with plume abatement (also called hybrid or wet/dry) is an evaporative cooling tower combined with a dry heat exchanger, used to abate the cooling tower plume. This is the best available solution where local constraints are such that the presence of plume is not accepted in normal […]

FLOW CONTROL VALVES

FLOW CONTROL VALVES Flow Control Valves are used to reduce the rate of flow in a section of a pneumatic circuit, resulting in a slower actuatWe offer two types of air flow control valves. Their selection and placement within a pneumatic circuit will greatly affect the function of an actuator.or speed. Unlike a Needle Valve, […]

Cooling Tower Processes

Cooling Tower Processes Cooling Towers Efficient cooling of water or other liquids or condensation of steam or other vapours with atmospheric air following the principles of the evaporative cooling or of the dry cooling. Dry air cooling – closed cooling circuit no water consumption no plume dissipation low pump power consumption Evaporative...

Gas–Liquid Exchanger

About Gas–Liquid Exchanger: In Gas–Liquid Exchanger type, one fluid is a gas (more commonly, air) and the other a low-pressure liquid (more commonly, water) and are readily separable after the energy exchange. In either cooling of liquid (water) or humidification of gas (air) applications, liquid partially evaporates and the vapor is carried...

Indirect-Contact Heat Exchanger

ABOUT Indirect-Contact Heat Exchangers: In an Indirect-Contact Heat Exchangerr, the fluid streams remain separate and the heat transfers continuously through an impervious dividing wall or into and out of a wall in a transient manner. Thus, ideally, there is no direct contact between thermally interacting fluids. This type of heat exchanger, also...

Fluid heat exchangers

About Fluid heat exchangers: Fluid heat exchangers with a gas passing upwards through a shower of fluid (often water), and the fluid is then taken elsewhere before being cooled. This is commonly used for cooling gases whilst also removing certain impurities, thus solving two problems at once. It is widely used in espresso machines as […]

Regenerative Heat Exchanger

About Regenerative Heat Exchanger: In a regenerative heat exchanger, the same fluid is passed along both sides of the exchanger, which can be either a plate heat exchanger or a shell and tube heat exchanger. Because the fluid can get very hot, the exiting fluid is used to warm the incoming fluid, maintaining a near […]

Recuperative Heat Exchangers

About Recuperative Heat Exchangers: The two types of heat exchangers most used are the Pre-heat systems, the Recuperative heat exchangers and Regenerative heat exchange type systems. Recuperative systems are also known as shell and tube type heat exchangers. In these heat exchangers, a stream of cold process gas passes through a series of tubes and...

Fluid heat exchangers

About Fluid heat exchangers: Fluid heat exchangers with a gas passing upwards through a shower of fluid (often water), and the fluid is then taken elsewhere before being cooled. This is commonly used for cooling gases whilst also removing certain impurities, thus solving two problems at once. It is widely used in espresso machines as […]

Pillow plate heat exchanger

ABOUT PILLOW PLATE HEAT EXCHANGER: A pillow plate heat exchanger is commonly used in the dairy industry for cooling milk in large direct-expansion stainless steel bulk tanks. The pillow plate allows for cooling across nearly the entire surface area of the tank, without gaps that would occur between pipes welded to the exterior of the […]

Microchannel heat exchangers

About Microchannel heat exchangers: Microchannel heat excahngers are heat exchangers in which (at least one) fluid flows in lateral confinements with typical dimensions below 1 mm. The most typical such confinement are microchannels, which are channels with hydraulic diameter  below 1 mm. Microchannel heat exchangers can be made from metal,...

Direct contact heat exchangers

About Direct Heat Exchangers: Direct contact heat exchangers involve heat transfer between hot and cold streams of two phases in the absence of a separating wall. Thus such heat exchangers can be classified as: Gas – liquid Immiscible liquid – liquid Solid-liquid or solid – gas Descripition: Most direct contact heat exchangers fall under the...

Phase-change heat exchangers

About Phase-change heat exchangers: Phase-change heat exchangers is to heating up or cooling down fluids in just a single phase, heat exchangers can be used either to heat a liquid to evaporate (or boil) it or used as condensor to cool a vapor  and condense  it to a liquid. In chemical plants  and refineries ,reboilers  […]

Dynamic scraped surface heat exchanger

ABOUT DYNAMIC SCRAPED SURFACE HEAT EXCHANGER: Dynamic scraped surface heat exchanger is mainly used for heating or cooling with high-viscosity products, crystallization  processes, evaporation  and high-fouling applications. Long running times are achieved due to the continuous scraping of the surface, thus avoiding fouling and achieving a...

Double Walled Tube Heat Exchangers

ABOUT DOUBLE WALLED TUBE HEAT EXCHANGERS: Double walled tube has a purge passage coiled through the middle of the tube wall. The bi-walled tube should be used when the heat exchanger is part of critical equipment design or is primarily safety related. APPLICATIONS: When the exchanger is in contact with hazardous material i.e., cooling Tritium...

Plate and shell heat exchanger

About Plate and shell heat exchanger: A third type of heat exchanger is a plate and shell heat exchanger, which combines plate heat exchanger with shell and tube heat exchanger technologies. The heart of the heat exchanger contains a fully welded circular plate pack made by pressing and cutting round plates and welding them together. […]

Plate heat exchangers

OVERVIEW: Another type of heat exchanger is the Plate heat exchangers. These exchangers are composed of many thin, slightly separated plates that have very large surface areas and small fluid flow passages for heat transfer. Advances in gasket and brazing technology have made the plate-type heat exchanger increasingly practical. In HVCA...

Spiral heat exchangers

OVERVIEW: Spiral heat exchangers modification to the perpendicular flow of the typical HCHE involves the replacement of shell with another coiled tube, allowing the two fluids to flow parallel to one another, and which requires the use of different design calculations.These are the Spiral Heat Exchangers (SHE), which may refer to a helical (coiled)...

Fin Fan Cooler

OVERVIEW: Fin fan cooler side is usually considered clean service, although some customers will specify an fin fan cooler-fouling factor as a result of airborne contaminants. Usually a fouling factor is only included for the process side of the cooler. The fouling factor is actually a resistance to heat transfer and is actually added to […]

Fin Fan Cooler

Fin fan cooler is usually considered clean service, although some customers will specify an airside-fouling factor as a result of airborne contaminants. Usually a fouling factor is only included for the process side of the cooler. The fouling factor is actually a resistance to heat transfer and is actually added to the other resistances due...

Hydraulic Oil Cooler

Hydraulic oil cooler mechanical power can be generated in various ways, and electrical as well as pneumatic systems are alternatives to hydraulic power generation systems. Mechanical power is used in a variety of applications such as pumps, motors and valves. The pump converts a small amount of mechanical power into hydraulic power, the valve...

Water heat exchanger

Water Heat Exchanger and other related products for the HVAC and process industries. We provide low maintenance and durable water Heat Exchanger with unique designs and high heat transfer rates. Not only will our Heat Exchanger work for your industrial or residential environment, however severe the conditions, they will require very little...

Double Pipe Heat Exchanger

A Double pipe heat exchanger is one of the simplest form of Shell and Tubular Heat Exchanger. Here, just one pipe inside another larger pipe. To make an Unit very Compact, The Arrangement is made Multiple Times and Continues Serial and Parallel flow. One fluid flows through the inside pipe and the other flows through […]

Aluminium Heat Exchanger

Aluminium Heat Exchanger is a device built for efficient heat transfer from one fluid to another, whether the fluids are separated by a solid wall so that they never mix, or the fluids are directly contacted. When selecting a Aluminium Heat Exchanger technology, coolant compatibility with wetted surfaces must be considered. A copper fluid path...

CROSS FLOW COOLING TOWER

Cross flow cooling tower offer excellent, easy accessibility of all key components such as fill, drift eliminators, mechanical equipment and water distribution system. This takes out a lot of the hassle for your maintenance personnel. Tipo Heat Exchangers Cooling Towers’ cross flow cooling tower are available in various cell sizes and various...

FRP SQUARE TYPE COOLING TOWER

FRP Square Type Cooling Tower belong to the Counter-Flow Square Shaped Cooling towers. The main features of FRP Square Type Cooling Tower are even water distribution through solid nozzles, minimum drift loss, etc. Our FRP Square Type Cooling Tower is manufactured using the best quality raw-material and consumes less power. We provide FRP Square...
1 17 18