AIR COOLED SCREW CHILLER:

General Description

Air Cooled Screw Chiller is suitable for medium-large scale industrial cooling or HVAC, widely applied in central cooling project in plastic factory, chemical factory, etc.

Easy installation, with no need for cooling tower.

Design features

  • -Water temperature range 5ºC to 35ºC.
  • -Bitzer semi-hermetic screw compressor.
  • -4 grade capacity control, 25%-50%-75%-100%.
  • -Shell and tube evaporator, high efficiency and cleanable(plat type available on request).
  • -Aluminum fin type condenser with adequate heat exchanging surface.
  • -Refrigeration solenoid valve, to protect compressor when stop.
  • -Refrigerant sight glass, to further monitor the refrigerant status in the system, so to check the unit running status.
  • -Siemens PLC control, overall monitoring of unit running status.
  • -Axial fan motor, with independent motor support bracket.
    -Multi-protection devices to make sure the chiller and the equipment running safety.
  • -Schneider electrical components.
  • -Danfoss/Emerson thermal components.

Unit Safety Protection

  • -Compressor internal protection
  • -Over current protection
  • -High/low pressure protection
  • -High discharge temperature alarm
  • -Over temperature protection
  • -Flow switch
  • -Phase sequence/phase missing protection
  • -Anti freezing protection

Water-cooled Screw Type Chiller

General Description

water cooled screw chiller is suitable for medium-large scale industrial cooling or HVAC, widely applied in central cooling project in plastic factory, chemical factory, etc.

Small installation area required, no need for ventilation.

Design features

  • -Water temperature range 5ºC to 35ºC.
  • -Bitzer semi-hermetic screw compressor.
  • -4 grade capacity control, 25%-50%-75%-100%.
  • -Shell and tube evaporator, high efficiency and cleanable(plat type available on request).
  • -Shell and tube condenser with adequate heat exchanging surface.
  • -Refrigeration solenoid valve, to protect compressor when stop.
  • -Refrigerant sight glass, to further monitor the refrigerant status in the system, so to check the unit running status.
  • -Siemens PLC control, overall monitoring of unit running status.
  • -Multi-protection devices to make sure the chiller and the equipment running safety.
  • -Schneider electrical components.
  • -Danfoss/Emerson thermal components.

Unit Safety Protection

  • -Compressor internal protection
  • -Over current protection
  • -High/low pressure protection
  • -High discharge temperature alarm
  • -Over temperature protection
  • -Flow switch for both chilled water and cooling water
  • -Phase sequence/phase missing protection