Blog

                              Cross Flow Cooling Towers

Product Description:

Cross flow cooling towers is available in single cell cooling capacity from 100 tr to 2000 tr. Our range of cross flow type cooling tower including SFID (single flow induced draft) and DFID (double flow induced draft) cooling towers. In cross flow type cooling tower the water flows vertically through the fills while the air flows horizontally across the flow of the falling water. Because of this, air does not have to pass through the distribution system, permitting the use of gravity flow hot water distribution basins mounted at the top of the unit above the fills.

Salient Features:

  • Easy maintenance by design
  • Do not require any elaborate pillar foundations, can be placed on any flat surface
  • All structural in HDG Steel, SS 304 and SS 316 available upon request.
  • Adjustable pitch axial flow, dynamically balanced aluminum fans
  • Casings of FRP (Fibre Reinforced Plastics) for durability and strength
  • All joints fastened with SS 304 fasteners
  • Uniformity in water dispersion through flower pot target nozzles
  • Capacities 10TR to 1500TR , in single cell
  • Water flow 5 m3/h to 1000 m3/h, in single cell
  • Delta T (Temperature drop) 4°C to 20°C, in single cell
  • Low pumping Head
  • Lower first cost pumping systems
  • Lower annual energy consumption & Operating Costs
  • Easy maintenance access to distribution nozzles
  • Low static pressure drop
  • Reduced Drift
  • Reduced re-circulation
  • More air / Fan Hp
  • Lower energy & Operating Costs

Applications

  • HOSPITALS, MALLS, THEATERS
  • Air Conditioned Halls
  • A/C plant & cold rooms
  • Chemical industries
  • Dairy ,Citrus and other food processing industries
  • Distilleries and Breweries plants
  • Industries heat process
  • Oil refineries

Overview of Cross Flow Cooling Towers

  • Cross flow induct draft technology is employed
  • Heat Transfer Media: Pvc Splash Bar
  • The Modular Series Cooling Tower is available in both single cell and multi cell as per the demands of the customers
  • Fiber Glass Reinforce Plastic is the construction material of the cooling tower
  • Clean water and industrial water are the choices of fills
  • Structural Component: Mild Steel Hot Dipped Galvanized.

Technical Function

The tower design incorporates a FRP distribution basin with number of flower type target nozzles in it and is located at the tower top. The water, by gravity, is dispersed over the fill media uniformly and water is allowed to pass vertically down along the honey comb fills. The fan coupled directly to the motor is placed horizontally to draw air across the fill media. A small portion of water is evaporated which removes the heat from the remaining water. In warm moist air is drawn to the horizontally placed fan / motor and is discharged through the fan deck, to the atmosphere. The resultant cold water is collected at the cooling tower collection sump from where it is re-circulated to the application

Technical Data
FSX12.12 KSN 612 KSN 619 KSN 627
Material PVC PP PP PP
Specific surface height [m²/m³] 243 240 150 125
Corrugation height [mm] 12 12 19 27
Max. installation height [mm] 2400 2200 2200 2200
Max. width [mm] 600 600 600 600
Installation depth [mm] 300 / 600 / 900 300 / 600 300 / 600 300 / 600
Max. application temp. [°C] 55 75 75 75
Void ratio [%] > 97 > 97 > 97 > 97
Images:

Cross Flow Cooling Towers:

Related image

Image result for cross flow cooling towers